ibus: Handle error when getting the D-Bus machine ID

It is possible for retrieving the machine ID to fail, either because
dbus was installed incorrectly (machine ID absent or corrupt), or in
32-bit builds, because stat() on the machine ID fails with EOVERFLOW
if it has an out-of-range timestamp or inode number.

dbus has historically treated this as a faulty installation, raising
a warning which by default causes the process to crash. Unfortunately,
dbus_get_local_machine_id() never had a way to report errors, so it has
no alternative for that (bad) error handling.

In dbus >= 1.12.0, we can use dbus_try_get_local_machine_id() to get
the same information, but with the ability to cope gracefully with
errors. ibus won't work in this situation, but that's better than
crashing.

Mitigates: https://github.com/ValveSoftware/steam-for-linux/issues/9605
Signed-off-by: Simon McVittie <smcv@collabora.com>
This commit is contained in:
Simon McVittie
2023-06-20 13:22:55 +01:00
committed by Sam Lantinga
parent 3ddbeab88f
commit 91198baed4
3 changed files with 49 additions and 1 deletions

View File

@@ -33,10 +33,16 @@ static SDL_DBusContext dbus;
static int LoadDBUSSyms(void)
{
#define SDL_DBUS_SYM2_OPTIONAL(TYPE, x, y) \
dbus.x = (TYPE)SDL_LoadFunction(dbus_handle, #y)
#define SDL_DBUS_SYM2(TYPE, x, y) \
if (!(dbus.x = (TYPE)SDL_LoadFunction(dbus_handle, #y))) \
return -1
#define SDL_DBUS_SYM_OPTIONAL(TYPE, x) \
SDL_DBUS_SYM2_OPTIONAL(TYPE, x, dbus_##x)
#define SDL_DBUS_SYM(TYPE, x) \
SDL_DBUS_SYM2(TYPE, x, dbus_##x)
@@ -77,6 +83,7 @@ static int LoadDBUSSyms(void)
SDL_DBUS_SYM(dbus_bool_t (*)(const DBusError *), error_is_set);
SDL_DBUS_SYM(void (*)(DBusError *), error_free);
SDL_DBUS_SYM(char *(*)(void), get_local_machine_id);
SDL_DBUS_SYM_OPTIONAL(char *(*)(DBusError *), try_get_local_machine_id);
SDL_DBUS_SYM(void (*)(void *), free);
SDL_DBUS_SYM(void (*)(char **), free_string_array);
SDL_DBUS_SYM(void (*)(void), shutdown);
@@ -502,4 +509,38 @@ void SDL_DBus_PumpEvents(void)
}
}
}
/*
* Get the machine ID if possible. Result must be freed with dbus->free().
*/
char *SDL_DBus_GetLocalMachineId(void)
{
DBusError err;
char *result;
dbus.error_init(&err);
if (dbus.try_get_local_machine_id) {
/* Available since dbus 1.12.0, has proper error-handling */
result = dbus.try_get_local_machine_id(&err);
} else {
/* Available since time immemorial, but has no error-handling:
* if the machine ID can't be read, many versions of libdbus will
* treat that as a fatal mis-installation and abort() */
result = dbus.get_local_machine_id();
}
if (result) {
return result;
}
if (dbus.error_is_set(&err)) {
SDL_SetError("%s: %s", err.name, err.message);
dbus.error_free(&err);
} else {
SDL_SetError("Error getting D-Bus machine ID");
}
return NULL;
}
#endif

View File

@@ -75,6 +75,7 @@ typedef struct SDL_DBusContext
dbus_bool_t (*error_is_set)(const DBusError *);
void (*error_free)(DBusError *);
char *(*get_local_machine_id)(void);
char *(*try_get_local_machine_id)(DBusError *);
void (*free)(void *);
void (*free_string_array)(char **);
void (*shutdown)(void);
@@ -99,6 +100,7 @@ extern void SDL_DBus_ScreensaverTickle(void);
extern SDL_bool SDL_DBus_ScreensaverInhibit(SDL_bool inhibit);
extern void SDL_DBus_PumpEvents(void);
extern char *SDL_DBus_GetLocalMachineId(void);
#endif /* HAVE_DBUS_DBUS_H */

View File

@@ -411,7 +411,12 @@ static char *IBus_GetDBusAddressFilename(void)
(void)SDL_snprintf(config_dir, sizeof(config_dir), "%s/.config", home_env);
}
key = dbus->get_local_machine_id();
key = SDL_DBus_GetLocalMachineId();
if (key == NULL) {
SDL_free(display);
return NULL;
}
SDL_memset(file_path, 0, sizeof(file_path));
(void)SDL_snprintf(file_path, sizeof(file_path), "%s/ibus/bus/%s-%s-%s",